- Data Brochure
Boiler Control 265
D 265
07/10
1 of 36 © 2010 D 265 - 07/10
The tekmar Boiler Control 265 can control the supply water temperature on up to three modulating boilers based on outdoor
temperature or setpoint requirements. The control can be set to control up to two modulating boilers based on outdoor temperature
or domestic hot water requirements. A large easy to read display provides current system temperatures and operating status. The
control has outputs for a primary pump, individual boiler pumps, and either a combustion air damper or an alert.
Additional functions include:
• Outdoor Reset
Sequential or Parallel Modulation
Installer and Advanced access levels
Primary pump output
Individual boiler pump outputs
• Pump purging
Boiler demand for space heating loads
DHW demand for domestic hot water loads
Setpoint demand for setpoint loads
0 – 10 V (dc) BAS / EMS input
Test sequence to ensure proper component operation
Setback input for energy savings
CSA C US certified
• Pump exercising
Input
Universal
Sensor
Included
Input
Universal
Sensor
Included
Input
Outdoor
Sensor
Included
or
Input
0-10 V (dc)
External Signal
Input
Boiler
Demand
Output
Modulating
Boiler
Output
Boiler
Enable
Output
Pump
Output
Boiler
Enable
or
Pump
Input
Setpoint
or DHW
Demand
Input
115 V (ac)
Power Supply
Output
Primary
Pump
Input
Timer or Switch
Optional
Output
Combustion Air
or Alert
1
Com
2
Boil
Sup
3
Boil
Ret
4
Out
+
5
UnO
Sw
6
+
7
–+–+–
8
Mod2 mAMod1 mA
9 10 11 12 13
Prim
P1
L
14
N
15 16 17
1
18
1
19
2
20
2
21 22 23 24 25 26 27 28 29
Boil
Dem
30
Com
Dem
31
Setp/
DHW
Boiler Control 265
Three Modulating Boiler & DHW / Setpoint
Do not apply power
Mod3 mA Power Boiler Boiler
C.A./
Alert
Boiler 3 /
DHW
Boiler
Pump 1
Boiler
Pump 2
Boiler
Pump 3
H2037B
Menu Item
Boiler Demand
DHW / Setpoint Demand
WWSD
Modulation
Boiler Output (x10,000 BTU/hr)
External Input Signal
Offset / Priority Override
Test
off
not t
esting
red testing
red tes
ting paused
For maximum heat,
press & hold T
est for
3 seconds.
Meets Class B:
Canadian ICES
FCC Part 15
Date Code
Made in Canada by
tekmar Control Systems Ltd.
Power 115 V ±10% 60 Hz 600 VA
Relays 230 V (ac) 5 A 1/3 hp, pilot duty 240 VA
Demands 20 to 260 V (ac) 2 VA
Stand Alone
Advanced
External Input
Off
CA.
Off
Alert
Fixed Lead
First On / Last Off
First On / First Off
Soft Stop
Rotate
Parallel
Installer
Exercise
Sequential
Output
Modulating
Boiler
Output
Modulating
Boiler
or
Signal wiring must be rated at least 300 V.
Note:
Boiler, DHW,
or setpoint
demand must
be powered with
20 to 260 V (ac)
before the boiler
is able to fire.
Seitenansicht 0
1 2 3 4 5 6 ... 35 36

Inhaltsverzeichnis

Seite 1 - - Data Brochure

- Data BrochureBoiler Control 265D 26507/10 1 of 36 © 2010 D 265 - 07/10The tekmar Boiler Control 265 can control the supply water temperature o

Seite 2 - Menu Item

© 2010 D 265 - 07/10 10 of 36 Section C1: Boiler Reset (Stand Alone)FIRE DELAYThe Fire Delay is the time delay that occurs between the time

Seite 3

11 of 36 © 2010 D 265 - 07/10BOILER DESIGN TEMPERATUREThe boiler design supply temperature is the supply water temperature required to he

Seite 4 - Design SupplyDesign Supply

© 2010 D 265 - 07/10 12 of 36 Self AdjustingWater TemperatureBoil Target (Occupied)BoostBoil Target (UnOccupied)Boost setting - 20 minutes t

Seite 5 - 672 hours 720 hours

13 of 36 © 2010 D 265 - 07/10Section D1Domestic Hot Water (DHW)Section D2DHW w/ Low Temp BoilersSection D: Domestic Hot Water OperationSe

Seite 6 - Section B1

© 2010 D 265 - 07/10 14 of 36 DHWPumpPrimaryPumpBoilerPumpDHWPumpPrimaryPumpBoilerPumpDHW MODE 3 - DHW in Primary / Secondary no PriorityWhe

Seite 7 - MINIMUM MODULATION

15 of 36 © 2010 D 265 - 07/10If DHW is to be incorporated into a low temperature system such as a radiant heating system, a mixing device

Seite 8

© 2010 D 265 - 07/10 16 of 36 Section E1: SetpointNote: Setpoint operation is only available when DHW MODE is set to OFF.SETPOINTThe control

Seite 9

17 of 36 © 2010 D 265 - 07/10Section F1: External InputDHW or Setpoint operation is available during External Input operation. Boiler Dem

Seite 10 - Section C1

© 2010 D 265 - 07/10 18 of 36 Section G1: Pump OperationPRIMARY PUMP OPERATIONThe primary pump operates under the following conditions:• A

Seite 11

19 of 36 © 2010 D 265 - 07/10 CAUTIONImproper installation and operation of this control could result in damage to the equipment and poss

Seite 12

© 2010 D 265 - 07/10 2 of 36 How To Use The Data BrochureUser InterfaceTable of ContentsInstallation ...

Seite 13 - Section D2

© 2010 D 265 - 07/10 20 of 36 2930BoilDemComDem24 to 230 V (ac)3031ComDemSetp/DHW24 to 230 V (ac)AquastatSTEP FOUR —————— ELECTRICAL CONNECT

Seite 14

21 of 36 © 2010 D 265 - 07/101516M24 to 230 V (ac)orLow Voltage AlertC.A. /Alert2324BoilerPump 124 to 230 V (ac)2122Boiler 3/DHW24 to 230

Seite 15 - DHW MODE 4 OPERATION

© 2010 D 265 - 07/10 22 of 36 Converting the 0 - 20 mAOutput to Operate a 0 - 10 V (dc) Device6+7–Mod 1 mA0-10 VdcActuating Motor500 Ω resis

Seite 16 - Section E1

23 of 36 © 2010 D 265 - 07/10 SENSOR AND UNPOWERED INPUT CONNECTIONSDo not apply power to these terminals as this will damage the control

Seite 17 - Section F1

© 2010 D 265 - 07/10 24 of 36 STEP FIVE —————— TESTING THE WIRING GeneralEach terminal block must be unplugged from its header on the contro

Seite 18 - Section G1

25 of 36 © 2010 D 265 - 07/10141213 PrimP1 PowerLNNL115 V (ac)1615C.A./AlertM24 to 230 V (ac)orLow Voltage Alert Test the OutputsPrimary

Seite 19 - ——————

© 2010 D 265 - 07/10 26 of 36 Connecting the ControlMake sure all power to the devices and terminal blocks is off, and remove any remaining

Seite 20 - Do Not Apply Power

27 of 36 © 2010 D 265 - 07/10Stand AloneAdvancedExternal InputOffC.A.OffAlertFixed LeadFirst On / Last OffFirst On / First OffSoft StopRotate

Seite 21 - Connection to Operate

© 2010 D 265 - 07/10 28 of 36 Outdoor Current outdoor air temperature as measured by the outdoor sensor. This item is only available when th

Seite 22 - Actuating Motor

29 of 36 © 2010 D 265 - 07/10Adjust Menu (1 of 5)CRoom Occupied The desired room air temperature during the occupied period.This item is

Seite 23 - UnOccupied Switch

3 of 36 © 2010 D 265 - 07/10DisplaySymbol DescriptionBoiler DemandDHW / Setpoint DemandWWSDModulationBoiler Output (x10,000 BTU/hr)Extern

Seite 24 - 0 - 10 V (dc) 0 - 20 mAOR

© 2010 D 265 - 07/10 30 of 36 Adjust Menu (2 of 5)BBoiler Minimum The minimum allowed boiler target temperature. Check the boiler(s) manufac

Seite 25 - Boiler 3/

31 of 36 © 2010 D 265 - 07/10Adjust Menu (3 of 5)BMaximum Modulation 1 The maximum percent modulation of the burner.This item is only ava

Seite 26 - DIP Switches

© 2010 D 265 - 07/10 32 of 36 Adjust Menu (4 of 5)BBoiler Mass 3 The thermal mass characteristics of Boiler 3.This item is only available wh

Seite 27

33 of 36 © 2010 D 265 - 07/10Adjust Menu (5 of 5)ESetpoint Mode Selects the Setpoint Mode of operation.This item is only available when D

Seite 28 - View Menu (1 of 1)

© 2010 D 265 - 07/10 34 of 36 TEST SEQUENCEEach step in the test sequence lasts 10 seconds.During the test routine, if a demand from the sys

Seite 29 - Installer

35 of 36 © 2010 D 265 - 07/10The control was unable to read a piece of information stored in its memory. Because of this, the control was

Seite 30

Technical Data 36 of 36Product design, software and literature are Copyright © 2010 by:tekmar Control Systems Ltd. and tekmar Control Systems, Inc.Al

Seite 31

© 2010 D 265 - 07/10 4 of 36 Section AGeneralOperationPage 4 - 6Section BBoilerOperationPage 6 - 10Section COutdoorResetPage 10 - 12Sequence of O

Seite 32

5 of 36 © 2010 D 265 - 07/10SETBACK (OCC and UNOCC)To provide greater energy savings, the control has a setback feature. With setback, th

Seite 33

© 2010 D 265 - 07/10 6 of 36 Section B1: Boiler ModulationSection B: Boiler OperationEXERCISINGThe control has a built-in exercising feature that

Seite 34 - Testing the Control

7 of 36 © 2010 D 265 - 07/10To calculate the Minimum Modulation, use the following formulae:For 4 to 20 mA:Minimum Modulation = 4 mA – Bo

Seite 35 - Error Messages

© 2010 D 265 - 07/10 8 of 36 BOILER MASSThe boiler mass setting allows the installer to adjust the control to the thermal mass of the type of hea

Seite 36 - Control Systems

9 of 36 © 2010 D 265 - 07/10MIN Segment OnMed (2)The Med setting is selected if the boiler that is used has a medium thermal mass. This m

Kommentare zu diesen Handbüchern

Keine Kommentare