The tekmarNet
®
Thermostat 553
is a communicating touchscreen
thermostat designed to operate one
or two heating stages, one cooling
stage, a fan and relative humidity.
Introduction
Energy Saving Features
Programmable Schedule
Zone Synchronization
Zone Post Purge
Warm Weather Shut Down
Cooling Interlock
Auto Heating Cycle
Temporary Hold
Away Scene Key
Additional Features
2 Auxiliary Sensor Inputs
tekmarNet
®
Communication
Compatible
Touchscreen Technology
Outdoor & Floor Temperature
Display
Backlight
Radiant Floor Heating & Cooling
Freeze Protection
Pump & Valve Exercising
Heat / Cool Priority
Air Group Master & Member
Network Schedule Master or
Member
Optimum Start
Scenes
Daylight Savings Time
Room Temperature Limiting
Relative Humidity Control
Seitenansicht 0
1 2 3 4 5 6 ... 51 52

Inhaltsverzeichnis

Seite 1 - Additional Features

tekmarNet® Thermostat 553Installation & Operation Manual553_D09/14ZoningReplaces: 04/13© 2014 553_D - 09/141 of 52A Watts Water Technologies Comp

Seite 2 - Table of Contents

© 2014 553_D - 09/1410 of 52A Watts Water Technologies CompanyHEAT ONHeat is turned on.COOL ONCooling is turned on.FANThe fan is turned on.%RHHumidi

Seite 3 - Important Safety Information

© 2014 553_D - 09/1411 of 52A Watts Water Technologies CompanyProgrammable SettingsPress and hold the Home button for 3 seconds to enter the program

Seite 4 - Installation

© 2014 553_D - 09/1412 of 52A Watts Water Technologies CompanySet Temp Menu (1 of 4)Setting DisplaySET HEAT ROOM Set the room heating temperature fo

Seite 5 - Mounting The Thermostat Base

© 2014 553_D - 09/1413 of 52A Watts Water Technologies CompanySetting DisplaySET HEAT FLOOR Set the floor heating temperature for the event.FloorA

Seite 6 - Compatible Sensors

© 2014 553_D - 09/1414 of 52A Watts Water Technologies CompanySetting DisplayCOOL MINIMUM ROOM LIMIT Set the minimum room cooling limit while in the

Seite 7 - Testing the Thermostat Wiring

© 2014 553_D - 09/1415 of 52A Watts Water Technologies CompanySetting DisplayTEMPORARY HOLDTemperature adjustment in the home menu can result in eit

Seite 8 -

© 2014 553_D - 09/1416 of 52A Watts Water Technologies CompanyTime Menu (1 of 1)Setting DisplayMINUTESSelect the current time minutes.Access Level:

Seite 9 - Switch Settings

© 2014 553_D - 09/1417 of 52A Watts Water Technologies CompanySchedule Menu (1 of 2)Setting DisplayEVENT 1The first programmable schedule time perio

Seite 10 - User Interface

© 2014 553_D - 09/1418 of 52A Watts Water Technologies CompanySetting DisplaySCHEDULESelect if the thermostat should change the temperature automati

Seite 11 - Programmable Settings

© 2014 553_D - 09/1419 of 52A Watts Water Technologies CompanyDisplay Menu (1 of 1)Setting DisplayUNITSSelect Fahrenheit or Celsius as the temperatu

Seite 12 - Set Temp Menu (1 of 4)

© 2014 553_D - 09/142 of 52A Watts Water Technologies CompanyTable of ContentsGetting Started ...

Seite 13 - Set Temp Menu (2 of 4)

© 2014 553_D - 09/1420 of 52A Watts Water Technologies CompanyScenes Menu (1 of 1)Setting DisplaySCENESEnable or disable the use of scenes (building

Seite 14 - Set Temp Menu (3 of 4)

© 2014 553_D - 09/1421 of 52A Watts Water Technologies CompanyMonitor Menu (1 of 4)Setting DisplayROOM AVERAGECurrent room temperature. Displays the

Seite 15 - Set Temp Menu (4 of 4)

© 2014 553_D - 09/1422 of 52A Watts Water Technologies CompanySetting DisplaySENSOR 2The temperature measurement from the sensor 2 input wiring term

Seite 16 - Time Menu (1 of 1)

© 2014 553_D - 09/1423 of 52A Watts Water Technologies CompanySetting DisplayFLOOR HIGHThe highest recorded floor temperature measurement. Touch the

Seite 17 - Schedule Menu (1 of 2)

© 2014 553_D - 09/1424 of 52A Watts Water Technologies CompanySetting DisplayCOOL W HOURSThe total number of hours the W relay has been operated for

Seite 18 - Schedule Menu (2 of 2)

© 2014 553_D - 09/1425 of 52A Watts Water Technologies CompanySetting DisplaySTATUS INFOToggles between “Status Info” and the current status includi

Seite 19 - Display Menu (1 of 1)

© 2014 553_D - 09/1426 of 52A Watts Water Technologies CompanySetting DisplayDEVICE COUNTProvides a count of all the tekmarNet® thermostats and setp

Seite 20 - Scenes Menu (1 of 1)

© 2014 553_D - 09/1427 of 52A Watts Water Technologies CompanySetup Menu (1 of 7)Setting DisplaySENSOR 1Select the auxiliary sensor input 1 type.Acc

Seite 21 - Monitor Menu (1 of 4)

© 2014 553_D - 09/1428 of 52A Watts Water Technologies CompanySetting DisplayW PUMPSelect whether the primary or mix system pump on a tekmarNet® sys

Seite 22 - Monitor Menu (2 of 4)

© 2014 553_D - 09/1429 of 52A Watts Water Technologies CompanySetting DisplayW2 PUMPSelect whether the primary or mix system pump on a tekmarNet® sy

Seite 23 - Monitor Menu (3 of 4)

© 2014 553_D - 09/143 of 52A Watts Water Technologies CompanyIt is your responsibility to ensure that this thermostat is safely installed according

Seite 24 - Toolbox Menu (1 of 3)

© 2014 553_D - 09/1430 of 52A Watts Water Technologies CompanySetup Menu (4 of 7)Setting DisplayY MINIMUM OFFSelect the compressor minimum off time.

Seite 25 - Toolbox Menu (2 of 3)

© 2014 553_D - 09/1431 of 52A Watts Water Technologies CompanySetup Menu (5 of 7)Setting DisplayW HEAT WWSDSelect the outdoor temperature above whic

Seite 26 - Toolbox Menu (3 of 3)

© 2014 553_D - 09/1432 of 52A Watts Water Technologies CompanySetup Menu (6 of 7)Setting DisplayAIR GROUP MASTERSelect if the thermostat is a master

Seite 27 - Setup Menu (1 of 7)

© 2014 553_D - 09/1433 of 52A Watts Water Technologies CompanySetup Menu (7 of 7)Setting DisplayCOOL PURGESelect the fan coil or furnace cooling pur

Seite 28 - Setup Menu (2 of 7)

© 2014 553_D - 09/1434 of 52A Watts Water Technologies CompanySequence of OperationHeat and Cool ApplicationsSection AThe 553 can operate in several

Seite 29 - Setup Menu (3 of 7)

© 2014 553_D - 09/1435 of 52A Watts Water Technologies CompanyRadiant Floor Baseload ---------------------------------------------- ----------------

Seite 30 - Setup Menu (4 of 7)

© 2014 553_D - 09/1436 of 52A Watts Water Technologies CompanyThe first stage operates on a temperature differential of ±0.7°F (±0.4°C) centered aro

Seite 31 - Setup Menu (5 of 7)

© 2014 553_D - 09/1437 of 52A Watts Water Technologies CompanyRoom Min and Max LimitsSection DHeating and cooling minimum and maximum temperature se

Seite 32 - Setup Menu (6 of 7)

© 2014 553_D - 09/1438 of 52A Watts Water Technologies CompanyHydronic System Supply Pump --------------------------------------- ------------------

Seite 33 - Setup Menu (7 of 7)

© 2014 553_D - 09/1439 of 52A Watts Water Technologies CompanyRelative Humidity OperationSection HRelative Humidity (RH) is controlled by maintainin

Seite 34 - Sequence of Operation

© 2014 553_D - 09/144 of 52A Watts Water Technologies CompanyCongratulations on the purchase of your new tekmar® thermostat.This manual will step th

Seite 35 - Two-Stage Heating

© 2014 553_D - 09/1440 of 52A Watts Water Technologies CompanyDX Coil Frost Protection --------------------------------------------- ---------------

Seite 36 - No Cooling

© 2014 553_D - 09/1441 of 52A Watts Water Technologies CompanyTime ClockSection JThe thermostat includes a time clock that is automatically visible

Seite 37 - Section F

© 2014 553_D - 09/1442 of 52A Watts Water Technologies CompanyTemperature AdjustmentSection KPermanent Adjustment - No Schedule -------------------

Seite 38 - Section G

© 2014 553_D - 09/1443 of 52A Watts Water Technologies CompanyProgrammable SchedulesSection LEnergy savings can be achieved by lowering the heating

Seite 39 - Section H

© 2014 553_D - 09/1444 of 52A Watts Water Technologies CompanyScenes (System Override)Section MScenes provide an easy way to save energy while away

Seite 40 - MemberMemberMaster

© 2014 553_D - 09/1445 of 52A Watts Water Technologies CompanyRecommendation on How to Use Scenes ----------------------------- -------------------

Seite 41 - Section J

© 2014 553_D - 09/1446 of 52A Watts Water Technologies CompanytekmarNet® AddressSection PWhen connected to a tekmarNet® system, each thermostat will

Seite 42 - Section K

© 2014 553_D - 09/1447 of 52A Watts Water Technologies CompanyError Message DescriptionSETUP MENU SAVE ERRORThe thermostat failed to read the Setup

Seite 43 - Section L

© 2014 553_D - 09/1448 of 52A Watts Water Technologies CompanyError Message DescriptionDISPLAY MENU SAVE ERRORThe thermostat failed to read the Disp

Seite 44 - Section M

© 2014 553_D - 09/1449 of 52A Watts Water Technologies CompanyError Message DescriptionDEVICE LIMITMore than 24 devices (thermostats or setpoint con

Seite 45 - Section N

© 2014 553_D - 09/145 of 52A Watts Water Technologies CompanyTo prevent the risk of personal injury and/or death, make sure power is not applied to

Seite 46 - Section Q

© 2014 553_D - 09/1450 of 52A Watts Water Technologies CompanyError Message DescriptionSYSTEM CONTROL LOST ERRORThe thermostat can no longer communi

Seite 47 - Troubleshooting

© 2014 553_D - 09/1451 of 52A Watts Water Technologies CompanyError Message DescriptionERROR AT THERMOSTATThere is an error on a different thermosta

Seite 48 - Error Messages (2 of 5)

All specifications are subjectto change without notice52 of 52 553_D - 09/14.Product design, software and literature are Copyright ©2014 by tekmar Con

Seite 49 - Error Messages (3 of 5)

© 2014 553_D - 09/146 of 52A Watts Water Technologies CompanyWallStudThermostatFrontThermostatBaseIf a gang box is not used:Feed the wiring through

Seite 50 - Error Messages (4 of 5)

© 2014 553_D - 09/147 of 52A Watts Water Technologies CompanyTesting tekmarNet®2 Wiring ------------------------------------------ -----------------

Seite 51 - Technical Data

© 2014 553_D - 09/148 of 52A Watts Water Technologies CompanyTesting tekmarNet®4 and Stand Alone Wiring -------------------------- -----------------

Seite 52

© 2014 553_D - 09/149 of 52A Watts Water Technologies CompanySwitch SettingsSwitchPositionAction1ONLOCK ACCESS LEVELThermostat is locally locked and